2ACC series spot light current controller is easy to install with small volume. With 256 grade brightness adjustment, can be controller by manual or computer.With trigger function, can control the light on/off by external signal. And it has power off saving function also.
1.Easy to operate, each channel can be controlled independently with high precision.
2.Digital display, button control, easy to understand.
3.Can communicate with PC by RS232.
4.With trigger, faster respond speed, high reliability.
5.Power off saving function.
6.Have a 5V 500mA output to supply to other device.
Parameters
Model | LTS-2ACC350/700/1000-4 | LTS-2ACC350/700/1500-2 | LTS-2ACC2500-2 | Remark |
Number of channels | 4 way | 2 way | 2way | |
Trigger voltage | High level 5-24V | Low level 0-1.5V | Low level 0-1.5V | |
Input voltage | AC 100-240V | |||
Input frequency range | 50/60Hz | |||
Luminance control method | Manual adjust by button, PC remote adjustio | |||
Luminance control mode | Constant-current | |||
Luminance control level | 256 level | |||
Storage function | Set-up parameter of luminance will be kept while power off | |||
Addition output voltage | 5V | This voltage strictly prohibit reverse connected | ||
Baud rate | 9600bps | |||
Communication mode | RS232 serial port communication |
Control panel specification < LTS-2ACC700-4>
Connection step:
Step 1: connected the light and controller (Reference to the picture on the right).
Step 2: if need the external trigger control, please connect the external trigger signal with the controller trigger interface.
Step 3: connect power (AC100-240V 50/60 Hz), press the red switch “-”, indicator light up, “o” uplifted, power on.
Step 4: If need to control the luminance by PC, please connect the PC with controller by RS232 data line in the power off status, then control by our demo program or the program you write yourself. Can set-up the each channel parameter manual when operated by serial port mode. That’s to say, the upper computer and controller all can set-up the parameter, no need mode swapping.
Trigger port setup < LTS-2ACC700-4 >
This series controller is high level trigger. Total 4 group trigger ports, each has +,- mark. To input high level to +,- port can achieve the trigger function.
Trigger introduction: when output initial state is open mode, input high level 5-24V to trigger port, light close.when output initial state is off mode, input high level 5-24V to trigger port, light on.
Specification: T1 is trigger delay time, T1≤80us T3≤80us.
Coding rule
Product | Model | One way output adjustable current | Total output power | One way Max.output power | Number ofchannels | Extenal triggervoltage | Remark |
---|---|---|---|---|---|---|---|
Constant current controller |
LTS-2ACC350-2 | 0-350mA | 2W | 1W | 2 | 0-1.5V | Have communication, trigger, luminance level display function |
LTS-2ACC700-2 | 0-700mA | 4W | 2W | 2 | |||
LTS-2ACC350-4 | 0-350mA | 4W | 1W | 4 | 5-24V | ||
LTS-2ACC700-4 | 0-700mA | 8W | 2W | 4 | |||
LTS-2ACC1000-4 | 0-1000mA | 12W | 3W | 4 | |||
LTS-2ACC1500-2 | 0-1500mA | 10W | 5W | 2 | 0-1.5V | ||
LTS-2ACC2500-2 | 0-2500mA | 16W | 8W | 2 |